Jumper cable/S104
For jumpering connections on the SA10 panel. |
|

|
Connection clips/S102
For medium voltage breakers. |
|

|
Connection clips/S102-A
For high voltage breakers. |
|

|
Bluetooth communication/S122
The bluetooth comunication kit allows the user to move up 100 meters (328 ft) away from the test object and excecute operations comfortable and safe. |
|

|
Thermal printer/121
Used to print out test results without PC. |
|

|
Transporting Case/S113
Used to store the SA10 during transport. With handle and wheels. Also serves as table when at the breaker. |
|

|
Soft cable bag/S114
Very handy to keep the cables when in field. |
|

|
DC Power supply/S140
A very light power supply for use in field. Weighs only 8 kg. Used to test minimum function voltage on the breaker coils. Comes with carrying case and cables. Voltage: 20 VDC to 250 VDC. Current: Up to 35A. |
AC/DC Power supply/S141
A very light power supply for use in field. Weighs only 8 kg. Used to test minimum function voltage on the breaker coils. Comes with carrying case and cables. Voltage: 20 VDC to 250 VAC/DC. Current: Up to 35A. |
|

|
Switch sync kit/S155
Used to measure the function of switch syncronisation breakers and the switch syncronisation relay. Also used for on-line testing of the circuit breaker.
Includes: FSU30 unit (S150) 3x Current clamps (PR30) |
|

|
Current Clamp/PR30
Used together with FSU30. |
|

|
FSU30 unit/S150
Allows for on-line monitoring and switch sync relay control. |
|

|
Digital rotary transducer/S108-B
This rotary digital transducer allows for very accurate motion testing. Type RSI503 2500 ppr. |
 |
Analogue linear transducer
TLH150 mm/S109
|
TLH225 mm/S110
|
TLH450 mm/S111
|
|

|
Universal fastening kit/S118
Use this universal kit to fasten your linear or rotary transducer to the breaker. Comes with a practical carrying case. |
|

|
HPL-B LTB-E(ABB)/S119-1
A variety of designated transducer fastenings for the rotary transducer S108-A can be provided for specific breaker types. This bracket is for HPL-B LTB-E breakers produced after 1997. |
|

|
HPL A/B (ABB)/S119-2
A variety of designated transducer fastenings for the rotary transducer S108-A can be provided for specific breaker types. This bracket is for HPL A/B breakers produced before 1997.
|
| |
BLK 52,152,222 (ABB)/S119-3
A variety of designated transducer fastenings for the rotary transducer S108-A can be provided for specific breaker types. This bracket is for breaker mechanisms BLK 52,152 and 222.
|
|

|
LTB 2 BLK 154/S119-4
A variety of designated transducer fastenings for the rotary transducer S108-A can be provided for specific breaker types. This bracket is for LTB2 with BLK 154 mechanism. |
| |
LTB 2 BLK 154/S119-5
A variety of designated transducer fastenings for the rotary transducer S108-A can be provided for specific breaker types. This bracket is for LTB2 with BLK 154 mechanism.
|
|

|
BLG 1002A/S119-6
A variety of designated transducer fastenings for the rotary transducer S108-A can be provided for specific breaker types. This bracket is for the BLG1002A mechanism. |
| |
LTB3 (switch sync)/S119-7
A variety of designated transducer fastenings for the rotary transducer S108-A can be provided for specific breaker types. This bracket is for LTB3 with switch sync application.
|
|

|
BLG102, 352/S119-8
A variety of designated transducer fastenings for the rotary transducer S108-A can be provided for specific breaker types. This bracket is for the BLG 102 or 352 mechanism. |
| |
EDF-SK/S119-11
Fastening EDF-SK before 2002.
|
| |
Fastenings bolts before 2002/S119-12
|
| |
HLC36-52/S119-13
Fastening HLC36-52.
|
| |
HLC 72,5-1600A/S119-14
Fastening HLC 72,5/1600A.
|
| |
HLC 72,5-2000A/S119-15
Fastening HLC 72,5/2000A.
|
| |
LTB-D 2000/S119-16
Fastening LTB-D 2000.
|
|

|
ELF AHMA 4/S119-17
Fastening ELF AHMA 4. |
| |
LT2001,-01 LT2000-25/S119-20
Fastening LT2001,-01 LT2000-25.
|
| |
LT6660-01, LT2000-25/S119-21
Fastening LT6660-01, LT2000-25.
|
| |
LTB-E, HPL-B with spline shaft/S119-22
Fastening LTB-E, HPL-B with spline shaft.
|
|

|
Mains cable/S201
1,8 m. Used for main supply to the SA10. |
|

|
Communication cable (RS232)/S202
1,8 m. Used for communicating between PC and SA10. |
|

|
Communication cable (RS232)/S202-A
10 m. Used for communicating between PC and SA10. |
|

|
Cable for motor/S203
4 m. Used for motor voltage supply and automatic measurement of the motor voltage and current. |
|

|
Cable for trip and close coils/S204
4 m. Used to supply voltage to breaker coils and to automatically measure coil voltage and coil current. |
|

|
Cable for digital transducer/S205
10 m. Used for connecting the rotary transducer S108-A to the SA0 unit.
|
Cable for analogue transducer/S206
10 m. Used for connecting analogue linear transducers to the SA10 unit.
|
|

|
Cable for static/dynamic resistance measuring/S207
10 m. For use with SA10 built-in micro Ohm meter to measure the main contact resistance as well as dynamic resistance. |
|

|
Contact timing cable/S208
10 m. Used for measuring of the breaker contact times. 1 twisted pair. |
| |
Contact timing cable/S208-A
10 m. Used for measuring of the breaker contact times. Specially designed for T-elements. 3 twisted leads.
|
|

|
Grounding cable/S210
5 m. Used for grounding the SA10 unit.
|
| |
|